Skip to content
Every protocol, the same toolkit

Protocols, information models and profiles

OT Fabric provides open-source building blocks for industrial communication, standardized information models and interoperable messaging. Each gets a pure Go library, a command-line tool where field work needs one, and tests against independent implementations.

Communication protocols
Define how devices exchange data: messages, services, addressing, sessions and transport behaviour on the wire. Modbus, OPC UA, BACnet/IP and more.
Information models
Define what the data means: standard devices, measurements, controls and their structure, apart from the protocol that carries them. SunSpec Modbus, IEC 61850 information model.
Application and messaging profiles
Define how a protocol is used for one interoperable application: topics, payloads, message flows, lifecycle and state. Sparkplug B.

Communication protocols

Define how devices exchange data: messages, services, addressing, sessions and transport behaviour on the wire.

Modbus Application Protocol V1.1b3

Modbus

The most widely deployed protocol in industrial automation: meters, inverters, batteries, drives and PLCs.

IEC 62541

OPC UA

The interoperability standard of industrial automation: a browsable address space, built-in security, and PubSub for data that fans out.

ISO 16484-5, Annex J

BACnet/IP

The standard protocol of building automation: HVAC, lighting, access control and energy metering.

IEC 60870-5-101

IEC 60870-5-101

Serial telecontrol between control centres and RTUs: the same data model as IEC 104, on point-to-point and multidrop lines, radio and modem links.

IEC 60870-5-102

IEC 60870-5-102

Reading integrated totals, the energy values of electricity meters, from meters and data concentrators over serial lines and modems; in Spain the basis of fiscal metering.

IEC 60870-5-103

IEC 60870-5-103

The informative interface of protection equipment: how a substation controller polls protection relays for their state, events, settings and fault records.

IEC 60870-5-104

IEC 60870-5-104

Telecontrol between grid control centres, substations and generation or storage assets.

IEC 61850-8-1 (MMS, GOOSE) and IEC 61850-9-2 (Sampled Values)

IEC 61850

IEC 61850 communication for substation automation: client/server services over MMS on TCP port 102, GOOSE events and Sampled Values streams on the station and process bus, all configured from SCL.

S7 communication over ISO-on-TCP (RFC 1006)

Siemens S7

Classic S7 communication with Siemens PLCs, for reading and writing data blocks, inputs, outputs and markers.

OpenADR 3.1.0 (OpenADR Alliance)

OpenADR

Demand response and dynamic tariffs between utilities or aggregators and the energy resources of their customers.

OCPP 1.6J, 2.0.1 and 2.1 (Open Charge Alliance)

OCPP

The protocol between EV charging stations and the management system that runs them: booting, authorizing, transactions, metering, smart charging and remote control.

IEEE 1815-2012 (Distributed Network Protocol)

DNP3

The SCADA protocol between control centres and the RTUs, IEDs and gateways in electric, water and oil and gas utilities: polls with time-stamped events, controls with select-before-operate, time synchronization and file transfer.

IEEE 2030.5-2018 and 2030.5-2023 (Smart Energy Profile 2.0)

IEEE 2030.5

The protocol between utilities or aggregators and distributed energy resources: inverters, batteries, EV chargers and meters register over mutual TLS and receive export limits, schedules and prices, with the CSIP profile for California and CSIP-AUS for Australia.

ODVA EtherNet/IP and CIP (The CIP Networks Library, Volumes 1 and 2); IEC 61158 and IEC 61784 (CPF 2)

EtherNet/IP

The industrial Ethernet protocol of programmable controllers, I/O adapters, drives and sensors: the Common Industrial Protocol (CIP) over TCP and UDP, with explicit messages to read and write objects and cyclic I/O between scanners and adapters.

PROFINET IO: IEC 61158-5-10 and 61158-6-10, IEC 61784-2 (CPF 3); PROFIBUS & PROFINET International

PROFINET

The industrial Ethernet of PLCs, remote I/O, drives and field devices: IO-Controllers find their IO-Devices by name with DCP, set them up over DCE/RPC and exchange their process data in cyclic real-time frames, with alarms, diagnosis and media redundancy.

ISO 11898-1 (classical CAN, CAN FD, CAN XL in the 2024 edition), ISO 15765-2 (ISO-TP); Bosch CAN 2.0 and CAN FD 1.0

CAN bus

The two-wire bus of vehicles, machines, batteries and chargers, and the transport that CANopen, SAE J1939 and UDS run on: short frames with an identifier that names the message and sets its priority, CAN FD for longer and faster frames, CAN XL for up to 2048 bytes, and ISO-TP for messages above one frame.

CiA 301 (EN 50325-4), CiA 302, 305 and 306; CiA 402 drives; CiA 1301 CANopen FD

CANopen

The application protocol that runs on CAN in machines, drives, lifts, medical and mobile equipment: an object dictionary per device, SDO to read and write it, PDOs for process data, NMT and heartbeats to manage the network, and EDS files that describe each device.

Over CAN bus
KNX Standard v3.0 (ISO/IEC 14543-3, EN 50090); KNXnet/IP: ISO 22510:2019; KNX Association

KNX

The home and building control standard of switches, dimmers, blinds, heating valves and presence detectors: devices exchange group telegrams over twisted pair, radio or IP, and KNXnet/IP connects them to IP networks through tunnelling and routing, with KNX IP Secure and Data Secure.

Information models

Define what the data means: standard devices, measurements, controls and their structure, apart from the protocol that carries them.

Application and messaging profiles

Define how a protocol is used for one interoperable application: topics, payloads, message flows, lifecycle and state.

At a glance

Communication protocols

Information models

Application and messaging profiles

Application profileBuilt onLibraryCLIInterop suite
Sparkplug BMQTTgo-sparkplugbsparkplugbctlsparkplugb-interop