Skip to content
CLI tools

modbusctl

Identify, fingerprint, scan, poll, decode and write Modbus devices over TCP, serial and TLS. Record them to MBCAP capture files and replay those as a simulated device.

Install

Linux and macOS

curl -fsSL https://get.otfabric.io/modbusctl | sh

Windows (PowerShell)

irm https://get.otfabric.io/modbusctl.ps1 | iex

CI, containers and device images

curl -fsSL https://get.otfabric.io/modbusctl | env OTF_UNMANAGED_INSTALL=/usr/local/bin sh

One static binary for Linux (x86-64, ARM64, ARMv7), macOS (Intel, Apple silicon) and Windows (x86-64, ARM64), with no runtime to install. The installer checks the release's SHA-256 checksum, installs per user without sudo, and upgrades in place when you run it again. Pin a release withOTF_VERSION. All install options. To build from source: make build in a checkout.

First commands

# What is this device? Device identification and Report Server ID
modbusctl client identify --ip 192.168.1.10 --server-id

# Which read function codes does each unit support?
modbusctl client fingerprint --ip 192.168.1.10 --unit 1-10

# Which register blocks are readable? Saved to an MBCAP capture
modbusctl client scan --ip 192.168.1.10 --algo smart --start 0 --end 5000 --output scan.mbcap

# Read and decode a 32-bit float, as JSON
modbusctl client decode --ip 192.168.1.10 --start 40001 --codec float32/layout:4321 --format json

# Poll four holding registers every second, until Ctrl-C
modbusctl client poll --ip 192.168.1.10 --start 100 --count 4

# Serve the scan as a simulated device on port 1502
modbusctl server static --input scan.mbcap --port 1502

The modbusctl guide walks through every command group, connection option and safety rule.

For scripts, CI and containers

modbusctl is as easy to read for a pipeline as for a person. It follows the same conventions as every OT Fabric tool, so a script written for one protocol carries over to the next.

The exit-code table
CodeMeaning
0Success
1Findings: the command completed and its result reports problems, such as a file that does not validate or a diagnosis with a failing check
2Usage: unknown command or flag, a missing argument
3Invalid input: a flag value, a file or a combination that does not make sense. Nothing was sent
4Transport: the connection could not be made, or was lost
5Timeout: the device did not answer in time
6Protocol: the device refused the request, or broke the protocol
7Partial success: a valid result was written, and it holds failures
8Unsupported: the device, or this platform, does not support what was asked
9Permission: the device or the operating system refused, such as raw-socket access without the capability
10Output or internal error
130Interrupted by Ctrl-C or SIGTERM before a result

Each tool uses the codes that apply to it; a code never changes meaning between tools.

In a Dockerfile

FROM debian:bookworm-slim
RUN apt-get update \
 && apt-get install -y --no-install-recommends ca-certificates curl \
 && curl -fsSL https://get.otfabric.io/modbusctl \
    | env OTF_UNMANAGED_INSTALL=/usr/local/bin sh \
 && rm -rf /var/lib/apt/lists/*
ENTRYPOINT ["modbusctl"]

Scripts, CI and containers has GitHub Actions and GitLab CI examples and shows how to use a simulator as a test fixture.

Protocols

Works with

The README on GitHub has the full feature list, examples and changelog.

go-modbus

Modbus client and server for the functions of the specification: TCP, RTU, ASCII, TLS and UDP, typed register codecs, pooling, retries and a PDU tap for recording.

go get github.com/otfabric/go-modbus
  • Modbus
GitHub

go-modbus-capture

MBCAP, the capture format for what Modbus devices answered and when, so a virtual device can serve it again. Go library and mbcapctl to inspect, verify, convert, filter, merge and repair captures.

go get github.com/otfabric/go-modbus-capture

go-modbus-trace

Read pcap and pcapng traces of Modbus/TCP offline: transactions, devices, poll patterns and address coverage. Library and mbtracectl, with timeline, sub-trace and MBCAP export.

go get github.com/otfabric/go-modbus-trace

go-sunspec

SunSpec over Modbus, both sides: discovers and decodes 112 built-in models into typed, scaled values, and serves simulated or real SunSpec devices.

go get github.com/otfabric/go-sunspec
  • SunSpec
GitHub

modbus-simulator

Deterministic, stateful Modbus TCP and TLS device simulator driven by JSON fixtures, with fault injection, request traces and CI assertions.

sunspecctl

Detect, list, read and poll SunSpec inverters, meters and batteries, and serve a simulated device from a JSON file or a capture of a real one.

  • SunSpec
GitHub

go-serial

Cross-platform serial ports for RS-232 and RS-485, with a Modbus RTU preset.

go get github.com/otfabric/go-serial

modbus-interop

Modbus reference stacks: libmodbus, PyModbus, digitalpetri, NModbus, tokio-modbus, j2mod, jsmodbus, modbus-esp8266 and modbus4j, over TCP, UDP and RTU over TCP.

sunspec-interop

SunSpec reference stacks in containers behind one contract: the SunSpec Alliance's pysunspec2 and cB-Sigma's sunspec and sunspec-sim, as devices and clients, with fixtures from the common models to the IEEE 1547 DER curves.

Modbus Trace Explorer

Open a packet trace of Modbus/TCP traffic and see it in Modbus terms: every request with its response, per device, per poll and per register. Then export the real traffic to replay as a simulated device.

SunSpec Explorer

Connect to a SunSpec inverter, meter or battery and see every model it exposes fully decoded. Read once or poll, record and export, without ever writing to the device.